Green IT Practices for Smaller Energy Use

green it practices

Green IT practices begin with measuring what your equipment draws, then switching off, consolidating and upgrading whatever wastes power. Whether you run a server room or an office full of laptops, you can cut energy use step by step.

This guide is part of the series on sustainability in business, and it covers the technology side: devices, servers and the power they draw.

Item Value
Data centers’ share of global electricity, 2022 1.3% (240-340 TWh)
Share of data center electricity demand used for cooling 40%
U.S. average data center PUE, 2023 1.6 (down from 2.5 in 2007)
Cooling energy cut in one Google data center example 40%
Annual saving from turning off one idle desktop 675 kWh (about $90) and 520 lbs of CO₂e
Global e-waste generated, 2022 62 Mt, of which 22% was recycled

The figures come from the University of Michigan Center for Sustainable Systems factsheet and a TechTarget article published June 12, 2024. Figures can change, so check the source before you rely on them.

Why IT energy use is worth your attention

Data centers are the heavy end of IT. The U.S. Department of Energy says they consume 10 to 50 times more energy than a typical office building in the same floor space and account for about 2% of the country’s total electricity use, according to TechTarget.

Worldwide, the University of Michigan factsheet puts data centers at 240-340 TWh in 2022, which is 1.3% of the global total. Inside these facilities, electricity demand is 40% computing, 40% cooling and 20% other IT equipment.

That split is why cooling gets as much attention as the servers themselves. It also explains why a few small changes to temperature, layout and utilisation can matter.

There is a business reason too. TechTarget notes that environmental, social and governance (ESG) initiatives have become a key measuring stick for customers, employees and investors, and that greener data centers can reduce energy and IT costs (TechTarget, June 12, 2024).

Start by measuring what you use

You cannot cut what you have not measured. TechTarget advises tracking overall electricity use first, then breaking it down into HVAC, server, infrastructure, network and storage consumption (source).

Data center teams also use power usage effectiveness (PUE), which divides total facility energy use by the energy used solely for IT equipment. The U.S. average annual PUE declined from 2.5 in 2007 to 1.6 in 2023, per the University of Michigan factsheet. The closer the ratio is to 1, the smaller the share of energy going to anything other than IT equipment.

A simple baseline looks like this:

  1. Collect electricity bills or meter readings for the space where your IT equipment sits.
  2. Split the total into cooling, servers, network and storage wherever your meters allow it.
  3. List every server, what it does and who still uses it.
  4. Repeat the measurement regularly, so you can see whether each change worked.

The International Energy Agency’s 2021 report made improving data collection and transparency one of its recommendations, as Federal News Network reported. The same principle applies at company scale: numbers first, then decisions.

Switch off, sleep and keep devices longer

Office devices add up across a whole workforce. Desktops use 65-250 W per hour when active and 1-6 W in sleep mode, while laptops use 20-50 W when active, according to the University of Michigan factsheet.

The same factsheet says turning off an idle desktop can save 675 kWh (an average of $90) and 520 lbs of CO₂e annually. It adds that the U.S. Department of Energy recommends enabling sleep mode after 20 minutes of inactivity and powering down after 2 hours of inactivity.

Quick wins that cost little:

  • Turn on power management on every machine through a central policy, not by asking each person.
  • Set sleep and shutdown timers in line with the Department of Energy guidance above.
  • Switch off monitors and peripherals at the end of the day.
  • Avoid unnecessary printing, and print double-sided on recycled paper when you must.
green it practices Laptop workstation
A laptop with a dark screen sits beside a mouse on a light surface.

Longer device life helps as well. The factsheet advises extending the life of personal computers to delay the energy and materials burdens of making new equipment. It puts a desktop system’s carbon footprint at 679 kg CO₂e and a laptop’s at 286 kg CO₂e, with over 75% coming from production (source).

Right-size your servers and cooling

Running all the servers in your data center 24/7 can lead to underutilization, TechTarget says. Some servers handle requests only at certain times, run applications rarely or no longer serve a purpose (source).

The fix is a short, repeatable routine:

  • Monitor how heavily each server is used.
  • Consolidate functions onto fewer machines where the data allows.
  • Virtualize some servers to shrink the physical footprint.
  • Decommission servers that no longer do useful work.

An EPA Energy Star manager told Federal News Network that EPA encourages consolidating and co-locating services at data centers, and would prefer fewer products doing lots of work efficiently. Idle products are not ideal for the owner or for energy use.

Cooling is the other lever. TechTarget says newer data center assets can safely run at higher temperatures, so the room can often be kept a little warmer to reduce the HVAC load. Calculate your cooling needs first, because excessive heat and humidity can damage IT equipment.

Layout matters too. Hot and cold aisle configurations group warmer assets together and make better use of HVAC vent placement (TechTarget).

Smart monitoring can go further. TechTarget describes AI tools and IoT sensors that adjust HVAC automatically, and says Google used such technology to reduce energy consumption in its data center cooling systems by 40%. That is one large operator’s example, so treat it as a sign of what is possible rather than a promise for a small server room (source).

Buy efficient hardware and retire old kit responsibly

Many legacy data center assets use more power, generate more heat and tolerate less than newer ones. TechTarget suggests installing efficient replacements at natural moments, such as end-of-life, parts replacement or maintenance, rather than in a rush (source).

When you buy, look for Energy Star certified devices and check Electronic Product Environmental Assessment Tool ratings. The University of Michigan factsheet estimates that if all U.S. servers met Energy Star standards, $1B in energy costs and 8.2 Mt of GHG emissions would be avoided yearly (source).

Storage is part of this. Federal News Network reported that EPA released new Energy Star specifications for storage products in August 2021. It also quoted EPA saying that technologies that reduce duplication and compress data can be huge energy savers (source).

Disposal is the last step. The factsheet says 62 Mt of e-waste was generated globally in 2022 and only 22% was recycled, and it urges you to recycle unused electronics (source).

Efficiency thinking also shapes how products and services are designed, which is the focus of the guide on sustainable innovation.

Where does your electricity come from?

Efficiency comes first, but the power supply matters too. TechTarget lists green energy alternatives such as geothermal cooling, wind power and hydroelectric power for organizations that want to reduce data center carbon emissions (source).

Large buyers are already moving. The University of Michigan factsheet says the ICT sector accounted for 60% of renewable power purchases in 2021.

Smaller organizations have fewer routes, but they do have some. The guide on renewable energy for businesses covers the supply side in more detail, and you can ask any cloud or colocation provider for the energy data behind its claims.

Frequently asked questions

What are green IT practices?

Show answer

They are habits and purchasing choices that reduce the energy and materials your technology uses. Typical examples are measuring power use, enabling sleep modes, consolidating servers, buying efficient hardware, recycling old equipment and choosing cleaner electricity.

Where should a small business start?

Show answer

Start by measuring, then turn on power management across your devices. The University of Michigan factsheet says turning off an idle desktop can save 675 kWh a year, so fleet-wide settings are a low-cost first step (source).

Does moving to the cloud make IT greener?

Show answer

It can help, because TechTarget notes that moving some resources to the cloud or virtualizing servers cuts the number of physical technologies you run (source). Ask the provider for energy data rather than assuming the result.

Is it safe to run a server room warmer?

Show answer

Often, with care. TechTarget says newer assets can safely run at higher temperatures, but you should calculate your cooling needs before turning up the thermostat so heat and humidity do not damage equipment (source).